Fire Audit Process
Printing extinguisher stickers, site setup, and the scan-to-check workflow
Recommended Method: Pre-Print, Then Visit
Print labels in the office before you go to site, then apply and scan on arrival. This is quicker and more reliable than trying to print from a phone over Bluetooth on site.
- In TrakNet, open Fire Audit in the sidebar.
- If the site already exists (e.g. Bowker), open it and check how many extinguishers are on the register. If you don't know the count yet, use Print blank stickers instead — print a few extra (e.g. 15 for a site you expect has 10-12) and register them as you find each unit.
- Click Print QR pack (known units) or Print blank stickers (unknown count), choose 2 per label (larger, for bigger extinguishers) or 4 per label (compact, for most jobs).
- In the print dialog: printer = Polono PL80E, paper size = 100 × 150mm, margins = None, scale = 100% / Default (never "Fit to page" — it blurs the QR).
- Cut along the dashed lines and take the printed sheet with you to site.
Taking pre-cut stickers on site is faster than printing per-unit — peel, stick, scan, next. No printer or signal needed once you're there.
On Site: Apply and Scan
- Open
traknet.app/audit on your phone (add it to your home screen once — it then opens like an app).
- Sign in with your TrakNet username and the site's Audit PIN (ask your admin if you don't have it).
- Tap Choose a site and pick the client and site you're at (or add it if it's new). Every sticker you scan next assumes this site until you change it.
- Stick a label on the extinguisher, then scan it (camera or in-app scanner).
- Blank sticker (shows its printed reference, e.g.
CFP-0042): opens Register this unit — confirm the site, add the label ("Ext 1 – Reception"), type, rating, and scan the manufacturer's serial barcode. Photograph the spec label if you can.
- Already registered unit: opens straight to the check screen — Pass or Fail (with a note and optional photo), or Record Service for a basic/extended service, recharge, or replacement.
- Repeat for every unit. The app tracks how many of the site's active extinguishers have been checked and completes the audit automatically once they're all done.
Printer Settings — Polono PL80E
| Setting | Value |
| Paper | Custom / 4" A6 — 100 × 150mm |
| Media | Gap, Gap: 3mm |
| Print Mode | Direct (no ribbon) |
| Speed | 50–76mm/s — slower prints darker, sharper text |
| Density | 10–13 — raise a little if text looks faint; too high can blur the QR |
| After Printing | Tear |
In Chrome's print dialog (not the printer driver dialog), Scale must be 100% / Default. "Fit to page" resizes the sheet and softens the QR.
2-Up vs 4-Up
2
2 per label — larger QR and text, easier to read at a glance. Use for bigger extinguishers or sites where labels need to stand out.
4
4 per label — compact, uses fewer labels. Good default for most jobs and for bulk blank-sticker packs.
Reference Codes
Every sticker printed carries a unique reference (CFP-0001, CFP-0002...), so a stack of blanks is never a stack of identical labels. Once registered, the reference sits under the extinguisher's location label on the sticker, in the app, and on the site register in TrakNet — the same code follows the unit everywhere.
Important Rules
🔑
The Fire Audit app needs the Audit PIN set in Fire Audit → Notification settings before anyone can sign in.
📍
Choose the site before scanning blanks — every new sticker registers against whichever site is currently selected.
🖨️
Print pre-emptively, not per-unit on site. There's no reliable way to print from the phone straight to the Bluetooth printer over the web app.
✉️
Completion reports, due reminders, and overdue chasers all go to the recipient list in Fire Audit → Notification settings — keep it current.